Dell-iDRAC-Fan-Controller

Docker 应用程序 from Selfhosters

概述

https://github.com/tigerblue77/Dell_iDRAC_fan_controller_Docker https://hub.docker.com/r/tigerblue77/dell_idrac_fan_controller/ All parameters are optional as they have default values (including default iDRAC username and password). IDRAC_HOST parameter can be set to "local" or to your distant iDRAC's IP address. Default value is "local". IDRAC_USERNAME parameter is only necessary if you're adressing a distant iDRAC. Default value is "root". IDRAC_PASSWORD parameter is only necessary if you're adressing a distant iDRAC. Default value is "calvin". FAN_SPEED parameter can be set as a decimal (from 0 to 100%) or hexadecimal value (from 0x00 to 0x64) you want to set the fans to. Default value is 5(%). CPU_TEMPERATURE_THRESHOLD parameter is the T°junction (junction temperature) threshold beyond which the Dell fan profile defined in your BIOS will become active again (to protect the server hardware against overheat). Default value is 50(°C). CHECK_INTERVAL parameter is the time (in seconds) between each temperature check and potential profile change. Default value is 60(s). DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. Default value is false. ipmi tool installation help: https://forums.Unraid.net/topic/129200-plug-in-nerdtools/ for installation and check this link for missing ipmi ipmi tool can't find /dev/ipmi0?: https://serverfault.com/questions/480371/ipmitool-cant-find-dev-ipmi0-or-dev-ipmidev-0

运行时参数

网络
bridge
特权
false

模板配置

IDRAC_HOSTVariable

IDRAC_HOST parameter can be set to local or to your distant iDRAC's IP address. Default value is local

默认值
local
价值
local
FAN_SPEEDVariable

FAN_SPEED parameter can be set as a decimal (from 0 to 100%) or hexadecimaladecimal value (from 0x00 to 0x64) you want to set the fans to. Default value is 5(%).

默认值
5
价值
5
CPU_TEMPERATURE_THRESHOLDVariable

CPU_TEMPERATURE_THRESHOLD parameter is the T°junction (junction temperature) threshold beyond which the Dell fan profile defined in your BIOS will become active again (to protect the server hardware against overheat). Default value is 50(°C).

默认值
50
价值
50
CHECK_INTERVALVariable

CHECK_INTERVAL parameter is the time (in seconds) between each temperature check and potential profile change. Default value is 60(s).

默认值
60
价值
60
IDRAC_USERNAMEVariable
默认值
root
价值
root
IDRAC_PASSWORDVariable
默认值
calvin
价值
calvin
DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSEVariable

parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. Default value is false.

默认值
false
价值
false
ipmi deviceDevice

Keep only if you are using a local connection and not a LAN connection. This will require your system to have ipmitool installed.

默认值
/dev/ipmi0
价值
/dev/ipmi0

下载统计数据

415,051
下载总数
26,734
本月
15,405
平均每月

长期下载总量

加载图表...

详细信息

存储库
tigerblue77/dell_idrac_fan_controller
最后更新2026-04-06
初见2023-01-31

在Unraid 上运行 Dell-iDRAC-Fan-Controller 。