https://github.com/tigerblue77/Dell_iDRAC_fan_controller_Docker https://hub.docker.com/r/tigerblue77/dell_idrac_fan_controller/ All parameters are optional as they have default values (including default iDRAC username and password). IDRAC_HOST parameter can be set to "local" or to your distant iDRAC's IP address. Default value is "local". IDRAC_USERNAME parameter is only necessary if you're adressing a distant iDRAC. Default value is "root". IDRAC_PASSWORD parameter is only necessary if you're adressing a distant iDRAC. Default value is "calvin". FAN_SPEED parameter can be set as a decimal (from 0 to 100%) or hexadecimal value (from 0x00 to 0x64) you want to set the fans to. Default value is 5(%). CPU_TEMPERATURE_THRESHOLD parameter is the T°junction (junction temperature) threshold beyond which the Dell fan profile defined in your BIOS will become active again (to protect the server hardware against overheat). Default value is 50(°C). CHECK_INTERVAL parameter is the time (in seconds) between each temperature check and potential profile change. Default value is 60(s). DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. Default value is false. ipmi tool installation help: https://forums.Unraid.net/topic/129200-plug-in-nerdtools/ for installation and check this link for missing ipmi ipmi tool can't find /dev/ipmi0?: https://serverfault.com/questions/480371/ipmitool-cant-find-dev-ipmi0-or-dev-ipmidev-0

Arguments d'exécution

Réseau
bridge
Privilégié
false

Configuration du modèle

IDRAC_HOSTVariable

IDRAC_HOST parameter can be set to local or to your distant iDRAC's IP address. Default value is local

Défaut
local
Valeur
local
FAN_SPEEDVariable

FAN_SPEED parameter can be set as a decimal (from 0 to 100%) or hexadecimaladecimal value (from 0x00 to 0x64) you want to set the fans to. Default value is 5(%).

Défaut
5
Valeur
5
CPU_TEMPERATURE_THRESHOLDVariable

CPU_TEMPERATURE_THRESHOLD parameter is the T°junction (junction temperature) threshold beyond which the Dell fan profile defined in your BIOS will become active again (to protect the server hardware against overheat). Default value is 50(°C).

Défaut
50
Valeur
50
CHECK_INTERVALVariable

CHECK_INTERVAL parameter is the time (in seconds) between each temperature check and potential profile change. Default value is 60(s).

Défaut
60
Valeur
60
IDRAC_USERNAMEVariable
Défaut
root
Valeur
root
IDRAC_PASSWORDVariable
Défaut
calvin
Valeur
calvin
DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSEVariable

parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. Default value is false.

Défaut
false
Valeur
false
ipmi deviceDevice

Keep only if you are using a local connection and not a LAN connection. This will require your system to have ipmitool installed.

Défaut
/dev/ipmi0
Valeur
/dev/ipmi0

Télécharger les statistiques

415,051
Total des téléchargements
26,734
Ce mois-ci
15,405
Moyenne / Mois

Total des téléchargements au fil du temps

Chargement du graphique...

Détails

Référentiel
tigerblue77/dell_idrac_fan_controller
Dernière mise à jour2026-04-06
Première vue2023-01-31

Exécutez Dell-iDRAC-Fan-Controller sur Unraid.

Dell-iDRAC-Fan-Controller est listé dans Community Apps pour Unraid OS. Explorez Unraid pour créer un serveur domestique flexible, un NAS ou un laboratoire domestique.