Dell-iDRAC-Fan-Controller

Aplicación Docker from Selfhosters

Visión general

https://github.com/tigerblue77/Dell_iDRAC_fan_controller_Docker https://hub.docker.com/r/tigerblue77/dell_idrac_fan_controller/ All parameters are optional as they have default values (including default iDRAC username and password). IDRAC_HOST parameter can be set to "local" or to your distant iDRAC's IP address. Default value is "local". IDRAC_USERNAME parameter is only necessary if you're adressing a distant iDRAC. Default value is "root". IDRAC_PASSWORD parameter is only necessary if you're adressing a distant iDRAC. Default value is "calvin". FAN_SPEED parameter can be set as a decimal (from 0 to 100%) or hexadecimal value (from 0x00 to 0x64) you want to set the fans to. Default value is 5(%). CPU_TEMPERATURE_THRESHOLD parameter is the T°junction (junction temperature) threshold beyond which the Dell fan profile defined in your BIOS will become active again (to protect the server hardware against overheat). Default value is 50(°C). CHECK_INTERVAL parameter is the time (in seconds) between each temperature check and potential profile change. Default value is 60(s). DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. Default value is false. ipmi tool installation help: https://forums.Unraid.net/topic/129200-plug-in-nerdtools/ for installation and check this link for missing ipmi ipmi tool can't find /dev/ipmi0?: https://serverfault.com/questions/480371/ipmitool-cant-find-dev-ipmi0-or-dev-ipmidev-0

Argumentos en tiempo de ejecución

Red
bridge
Privilegiado
false

Configuración de plantillas

IDRAC_HOSTVariable

IDRAC_HOST parameter can be set to local or to your distant iDRAC's IP address. Default value is local

Por defecto
local
Valor
local
FAN_SPEEDVariable

FAN_SPEED parameter can be set as a decimal (from 0 to 100%) or hexadecimaladecimal value (from 0x00 to 0x64) you want to set the fans to. Default value is 5(%).

Por defecto
5
Valor
5
CPU_TEMPERATURE_THRESHOLDVariable

CPU_TEMPERATURE_THRESHOLD parameter is the T°junction (junction temperature) threshold beyond which the Dell fan profile defined in your BIOS will become active again (to protect the server hardware against overheat). Default value is 50(°C).

Por defecto
50
Valor
50
CHECK_INTERVALVariable

CHECK_INTERVAL parameter is the time (in seconds) between each temperature check and potential profile change. Default value is 60(s).

Por defecto
60
Valor
60
IDRAC_USERNAMEVariable
Por defecto
root
Valor
root
IDRAC_PASSWORDVariable
Por defecto
calvin
Valor
calvin
DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSEVariable

parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. Default value is false.

Por defecto
false
Valor
false
ipmi deviceDevice

Keep only if you are using a local connection and not a LAN connection. This will require your system to have ipmitool installed.

Por defecto
/dev/ipmi0
Valor
/dev/ipmi0

Descargar estadísticas

415,051
Descargas totales
26,734
Este mes
15,405
Media / Mes

Descargas totales a lo largo del tiempo

Cargando gráfico...

Detalles

Repositorio
tigerblue77/dell_idrac_fan_controller
Última actualización2026-04-06
Visto por primera vez2023-01-31

Ejecute Dell-iDRAC-Fan-Controller en Unraid.

Dell-iDRAC-Fan-Controller se encuentra en Community Apps para Unraid OS. Explore Unraid para crear un servidor doméstico flexible, un NAS o un laboratorio doméstico.