Dell-iDRAC-Fan-Controller

Docker-Anwendung from Selfhosters

Übersicht

https://github.com/tigerblue77/Dell_iDRAC_fan_controller_Docker https://hub.docker.com/r/tigerblue77/dell_idrac_fan_controller/ All parameters are optional as they have default values (including default iDRAC username and password). IDRAC_HOST parameter can be set to "local" or to your distant iDRAC's IP address. Default value is "local". IDRAC_USERNAME parameter is only necessary if you're adressing a distant iDRAC. Default value is "root". IDRAC_PASSWORD parameter is only necessary if you're adressing a distant iDRAC. Default value is "calvin". FAN_SPEED parameter can be set as a decimal (from 0 to 100%) or hexadecimal value (from 0x00 to 0x64) you want to set the fans to. Default value is 5(%). CPU_TEMPERATURE_THRESHOLD parameter is the T°junction (junction temperature) threshold beyond which the Dell fan profile defined in your BIOS will become active again (to protect the server hardware against overheat). Default value is 50(°C). CHECK_INTERVAL parameter is the time (in seconds) between each temperature check and potential profile change. Default value is 60(s). DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. Default value is false. ipmi tool installation help: https://forums.Unraid.net/topic/129200-plug-in-nerdtools/ for installation and check this link for missing ipmi ipmi tool can't find /dev/ipmi0?: https://serverfault.com/questions/480371/ipmitool-cant-find-dev-ipmi0-or-dev-ipmidev-0

Laufzeit-Argumente

Netzwerk
bridge
Privilegiert
false

Konfiguration der Vorlage

IDRAC_HOSTVariable

IDRAC_HOST parameter can be set to local or to your distant iDRAC's IP address. Default value is local

Standard
local
Wert
local
FAN_SPEEDVariable

FAN_SPEED parameter can be set as a decimal (from 0 to 100%) or hexadecimaladecimal value (from 0x00 to 0x64) you want to set the fans to. Default value is 5(%).

Standard
5
Wert
5
CPU_TEMPERATURE_THRESHOLDVariable

CPU_TEMPERATURE_THRESHOLD parameter is the T°junction (junction temperature) threshold beyond which the Dell fan profile defined in your BIOS will become active again (to protect the server hardware against overheat). Default value is 50(°C).

Standard
50
Wert
50
CHECK_INTERVALVariable

CHECK_INTERVAL parameter is the time (in seconds) between each temperature check and potential profile change. Default value is 60(s).

Standard
60
Wert
60
IDRAC_USERNAMEVariable
Standard
root
Wert
root
IDRAC_PASSWORDVariable
Standard
calvin
Wert
calvin
DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSEVariable

parameter is a boolean that allows to disable third-party PCIe card Dell default cooling response. Default value is false.

Standard
false
Wert
false
ipmi deviceDevice

Keep only if you are using a local connection and not a LAN connection. This will require your system to have ipmitool installed.

Standard
/dev/ipmi0
Wert
/dev/ipmi0

Statistik herunterladen

415,051
Downloads insgesamt
26,734
Dieser Monat
15,405
Durchschnittlich / Monat

Gesamte Downloads im Laufe der Zeit

Tabelle laden...

Einzelheiten

Repository
tigerblue77/dell_idrac_fan_controller
Zuletzt aktualisiert2026-04-06
Erstmals gesehen2023-01-31

Führen Sie Dell-iDRAC-Fan-Controller auf Unraid aus.

Dell-iDRAC-Fan-Controller ist gelistet in Community Apps für Unraid OS. Erkunden Sie Unraid, um einen flexiblen Heimserver, ein NAS oder ein Heimlabor aufzubauen.