Brings the front-panel LCD on XikeStor NAS units back to life under Unraid. Out of the box the panel sits on "STARTING SYSTEM / PLEASE WAIT" forever, because the vendor's own OS drives it and Unraid has nothing that talks to it.
With this plugin the panel shows live data again, and its menu can shut down or reboot the server:
| Panel screen | Source on Unraid |
|---|---|
| CPU / SYS temperature | hwmon (coretemp/k10temp, ACPI or board sensor) |
| HDD1–HDD4 temperature | Unraid's disks.ini — never wakes spun-down disks (they show 0) |
| Total / used / free capacity | Array data disks, in GB |
| LAN1 / LAN2 IP, netmask, gateway | Auto-detected (skips loopback, Docker and VM interfaces), or configured |
| Menu → Shutdown / Reboot | Clean Unraid poweroff / reboot (can be disabled) |
| Menu → network settings, USB backup/eject | Ignored on Unraid (logged) |
Compatibility
Tested on a 4-bay XikeStor unit with the panel exposed as a Holtek USB HID device. Check yours with:
lsusb | grep -i 374a:b101 # expect: HOLTEK USB-HID AP
If your model shows a different ID, please open an issue with the lsusb output.
Requires Unraid 6.12+. No other dependencies: the daemon is PHP (part of Unraid) plus a tiny static helper binary that is built from source in this repo.
Install
Search XikeStor LCD in the Apps tab (once listed in Community Applications), or Plugins → Install Plugin and paste:
https://raw.githubusercontent.com/JamesSeymour/xikestor-lcd/main/xk_lcd.plg
Settings live under Settings → Utilities → XikeStor LCD. The daemon starts automatically at boot.
If you previously started the daemon from
/boot/config/go, remove those lines first.
Settings
| Setting | Default | Notes |
|---|---|---|
| Enable service | Yes | |
| HDD1–HDD4 slots | parity,disk1,disk2,cache |
Unraid disk names in panel order; use - for an empty slot |
| LAN1/LAN2 interfaces | auto | e.g. br0,eth1 |
| Allow Shutdown/Reboot from panel | Yes | |
| Refresh interval | 5 s |
Log: /var/log/xk_lcd.log (in RAM). Manual control: /usr/local/emhttp/plugins/xk_lcd/scripts/rc.xk_lcd {start|stop|restart|status}.
Known behaviour
- The panel cannot show free text. Its firmware draws fixed screens; the host only supplies values.
- After a panel Shutdown the panel waits for power to drop. It is powered from standby 5 V, so it only resets on a real power-off — a warm reboot from the Unraid UI does not clear it.
- After a panel Reboot the panel resets itself and re-enumerates on USB; the daemon reconnects automatically.
- Before the array starts, capacity shows 0.
Protocol
Reverse-engineered for interoperability. All traffic uses 9-byte HID feature reports on the
hidraw node (the 64-byte input/output reports in the descriptor are unused):
[0x00 report id] [marker] [cmd] [type] [d0] [d1] [d2] [d3] [checksum]
checksum = (255 - sum(bytes 0..7)) & 0xFF
marker = 0x00 host -> panel, 0x80 panel -> host
Host → panel (HIDIOCSFEATURE):
| cmd | type | data | meaning |
|---|---|---|---|
0x88 |
0, then 1 |
– | Init handshake; panel leaves "STARTING SYSTEM" |
0x03 |
1 CPU, 2 SYS, 3–6 HDD1–4 |
d0 = °C | Temperatures |
0x02 |
1 total, 2 used, 3 free |
u32 big-endian, GB | Capacity |
0x00 |
1/2 IP, 0x81/0x82 netmask, 0x41/0x42 gateway |
4 octets | LAN1/LAN2 |
0x08 |
1 |
4 octets | "Default" IP |
0x04 |
1 |
– | Ack: USB backup/eject finished |
Panel → host (HIDIOCGFEATURE, polled). Reads return the panel's pending action — or an
echo of the host's last write with the marker set to 0x80 (checksum adjusted), which must
be filtered out:
| frame | meaning |
|---|---|
00 80 00 00 00 00 00 00 7f |
Idle |
00 80 01 00 00 00 00 00 7e |
Shutdown requested |
00 80 01 01 00 00 00 00 7d |
Reboot requested |
00 80 02 <sel> <ip…> |
Network change requested * |
00 80 04 00 / 00 80 04 01 |
USB backup / eject requested * |
* Inferred from the vendor software's behaviour, not yet captured from a real panel. Shutdown and Reboot frames are confirmed on hardware. If you capture these, please open an issue with the log line.
Button navigation is handled inside the panel; only menu actions are reported.
How it works
src/xk_lcd.php— the daemon: gathers data, drives the panel, handles menu actions.src/xk_hidfeat.c— a ~60-line helper. The panel only speaks HID feature reports, which need theioctl()system call, and PHP has noioctl(and Unraid's PHP has no FFI). The daemon runs the helper as a co-process and exchanges one hex line per report with it.src/rc.xk_lcd— start/stop script;src/XikeStorLCD.page— the settings page.
The helper is compiled as a static musl binary (~60 KB, no runtime dependencies) and embedded
in the .plg; the installer verifies its SHA-256 before use.
Verifying the binary. The build is reproducible. On every push, CI
rebuilds the helper from src/xk_hidfeat.c on a clean Ubuntu 24.04 runner and fails unless the
result is byte-identical to the committed bin/xk_hidfeat; the run summary shows both hashes.
You can do the same locally with ./build_helper.sh (Ubuntu 24.04's musl-tools, or Docker).
Nothing on Unraid uses Python: PHP ships with Unraid, and the helper is self-contained.
Development
Source lives in src/. The plugin file is generated so everything stays in one place. The build
runs on your development machine and needs Python 3 there, plus musl-gcc or Docker for the helper:
./build_helper.sh # only when src/xk_hidfeat.c changes
python3 build.py --version 2026.10.24 --changes "- What changed"
Commit src/, bin/xk_hidfeat, and the regenerated xk_lcd.plg, templates/xk_lcd.xml and
ca_profile.xml. CI fails if any generated file is out of date with src/
(python3 build.py --check runs the same check locally).
Unraid detects updates from the version attribute, so bump it for every release. Set OWNER
(and optionally SUPPORT, your forum thread) at the top of build.py once.
Tests. ./tests/run_tests.sh (needs php, python3, gcc) runs syntax checks, verifies
the ioctl numbers against <linux/hidraw.h>, and drives the real daemon against a simulated
panel (tests/mock_helper.py) that reproduces the hardware's echo behaviour: handshake, data
push, echo filtering, USB reconnect, menu actions with power actions on and off. It runs in CI.
The daemon also runs standalone (with the helper next to it):
php xk_lcd.php --config my.cfg, or --test to send fixed test values once.
Disclaimer
Not affiliated with or endorsed by XikeStor. This is an independent implementation; no vendor code or binaries are included. Use at your own risk — the panel menu can power off your server.
Licence
MIT — see LICENSE.
Requirements
Categories
Download Statistics
Downloads by Month
Related apps
Explore more like this
Explore allDetails
https://raw.githubusercontent.com/JamesSeymour/xikestor-lcd/main/xk_lcd.plg